Home > PRODUCTS > Industrial UPS LF31-200 10-120kVA >

Industrial UPS LF31-200 10-120kVA

★:Equipped with both input and output isolation transformers and a dedicated voltage-stabilized bypass cabinet, it isolates grid disturbances at the source, delivering clean, stable power to critical loads.

★:Directly compatible with 220V DC panel battery banks, it eliminates the need for separate batteries, significantly reducing capital and maintenance costs for seamless integration into industrial power systems.

CONTACT US


Contact: home@dn-ups.com

Tel: 021 34553681

Phone: 18964032600, 18049827051

Add: No. 52 Xinjian East Road, Greenland S&T Island Plaza, Minhang District, Shanghai, China

DenbyePower® LF31-220 Series Industrial-grade UPS

Engineered for Harsh Industrial Environments · Standard Input/Output Isolation Transformers · Compatible with 220V DC Screen Battery Banks
⚡ Low-frequency Double Conversion Online
🔌 220VDC from DC Screen
🛡️ IP31/IP42 High Protection
🏭 6/12-pulse Rectifier Supported
🌀 Redundant Fault-tolerant Design

⚙️ Power Industry UPS / Power Plant UPS / DCS Control UPS / Dual Isolation UPS

Equipped with dual input & output isolation transformers and isolated voltage-regulated bypass cabinet. 220VDC standard, directly compatible with existing DC screen battery banks in substations and power plants — significantly reducing initial investment while providing the highest level of electrical isolation and impact resistance.

🔰 100% Front Maintenance
Wall-mounted / Cabinet Integration
🌡️ Graphene Coating + High-static Fans
Operates Without Air Conditioning
🔁 Dual Mains Input Supported
Full-path Fault Isolation
🧩 AC/DC Full Parallel Redundancy
99.9999% Availability

🏭 Typical Applications · Critical Infrastructure

🏭🏗️

Heavy Industry & Smart Manufacturing

Automotive production lines, metallurgical control systems, mining heavy equipment, precision machining PLC control, robotic welding lines. Withstands large motor start-up shocks and adapts to mixed inductive/capacitive loads.

  • Withstands ±100% load step shock
  • Operates with phase loss & phase reversal
  • Conformal coated PCB, dust & corrosion resistant
⚡🏭

Energy, Power & Petrochemical

Power plant DCS systems, nuclear power instrumentation, offshore oil & gas platforms, PV inverter stations, substation integrated automation. Directly utilizes 220V DC screen batteries for long backup time.

  • Temperature-compensated charging extends battery life
  • Back-feed protection ensures operational safety
  • Supports lead-acid/lithium batteries, max 80A charging
🚇🛫

Rail Transit & Aviation Hubs

High-speed rail traction substations, metro signaling systems, airport navigation/radar, port shore power systems. Adapts to voltage fluctuations and high-frequency harmonic interference for uninterrupted critical signals.

  • Generator compatible, seamless transfer
  • Redundant control power design
  • ModBus/RS485, seamless DCS/IoT integration
🏥💾

Data Centers & High-end Infrastructure

Supercomputing centers, 5G core rooms, semiconductor fabs, hospital imaging equipment, water treatment plants. Provides zero-interruption pure sine wave output to prevent data loss.

  • Output voltage regulation ±1%
  • 7-inch color touch screen with real-time power flow
  • 2000 event logs & component life alerts

🔋 Shared DC Screen Battery Bank · High ROI

220VDC version directly matches power plant/substation DC operating power, eliminating extra batteries and reducing footprint & maintenance costs. 1.5x oversized rectifier design delivers up to 80A fast charging. Optional battery temperature compensation extends battery life by over 30% in harsh environments.

✅ Lithium/lead-acid battery compatible
✅ Battery emergency trip interface
✅ Cold start without mains

🔌🔋⚙️

🛡️ Standard Input/Output Isolation Transformers

Full electrical isolation suppresses grid spikes (6kV/10kA), surges and common-mode interference. Optional output neutral directly grounded system delivers clean power for precision loads. Supports 100% unbalanced loads and large motor starting.

🌀 Isolated Bypass Cabinet with Voltage Regulation

Built-in isolated, voltage-regulated bypass ensures stable output during UPS maintenance or overload transfer, protecting loads from voltage fluctuations. Full galvanic isolation, zero neutral-ground voltage. External maintenance bypass optional. Dual independent mains input supported.

🔌 Rectifier & Input Characteristics

  • 6/12-pulse SCR rectifier optional
  • Dual mains input (main + bypass)
  • TVSS 40kA surge protection
  • Input PF ≥0.95 (higher for 12-pulse)
  • Generator compatible, harmonic filtering

🛡️ Output Characteristics

  • Standard output isolation transformer, full isolation
  • Full compatibility 0.7~1.0 load PF
  • 100% unbalanced load capability
  • Supports motor inductive & switching loads
  • ±100% load step impact resistance

🛡️ Engineered for Harsh Environments · Reliability & Longevity

🌪️ Extreme Environment Adaptability

  • Operating temp 0~40℃, storage -25℃~55℃
  • IP42 optional, dust/waterproof for offshore/mining
  • Conformal coated PCB + shockproof, salt-fog resistant
  • Patented thermal design, short operation on fan failure

⏳ 30-year Design Life · MTBF>200,000 Hours

  • Industrial-grade components, global top brands
  • Rectifier/inverter redundancy, component life management
  • 4-unit parallel, full AC/DC redundancy, true N+X

⛑️ Fault Tolerance & Safety

  • Redundant control power supply
  • Full-path fault isolation, 3-level ECB protection
  • Misoperation protection, safe sequential startup
  • Back-feed protection + battery emergency trip

⏱️ Long-life Design

  • Global brand key components (capacitor/fan/IGBT)
  • MTBF > 200,000hrs, 30-year design life
  • Graphene coating, operates without AC
  • Component life alert for fan/battery

📐 Physical Dimensions & Environment
Power Rating Dimensions(D×W×H mm) Net Weight(kg) IP Rating Operating Temp
10kVA~40kVA 800×800×1800 354~480 IP31(Standard)
/ IP42 Optional
0~40℃
Storage -25~55℃
60kVA~80kVA 800×1200×1800 680~910
100kVA~120kVA 800×1600×1800 1010~1620

📡 Smart Management & Industrial Connectivity

Standard RS232/RS485, 5DO/4DI dry contacts, supports ModBus RTU/SNMP protocols. Directly integrates with DCS or IIoT platforms for remote monitoring, battery management and alarm notifications. 7-inch touch screen with real-time power flow, fan/battery life alerts to reduce unplanned downtime.

📊 Component Life Management System
📝 2000 Event Logs
🌐 SNMP Card Optional
⚙️ Parameter Upload/Download


LF31-220 Series Industrial UPS — Protecting critical power from generation to smart manufacturing with isolation, DC sharing and redundant architecture.

Power Range: 10kVA ~ 120kVA | 220VDC Standard | Dual Isolation + Regulated Bypass | Custom Higher Protection Available